PTG6 Precision Thickness Gauge

When precision is key, the PTG6 has a measurement range of 0.15mm (0.006”) to 25.40mm (1.000”) with ±1% accuracy, across three measurement modes, Interface Echo (I-E), Echo-Echo (E-E), and Plastic Mode (PLAS). This gauge allows users to take measurements with pinpoint accuracy.

Calibration Options

The PTG6 has a number of calibration options. Using an uncoated sample of test material of a known thickness, the gauge can be calibrated using 1-Point calibration. Alternatively, the user can select one of 39 pre-set materials stored within the gauge including; aluminium, steel, stainless steel, cast iron, plexiglass, PVC, polystyrene and polyurethane.

The PTG6 also offers the additional calibration options of 2-Point & Velocity.

Data Output

Compatible with ElcoMaster® software, individual readings can be downloaded via USB to PC or similar device for further analysis.

 

PTG6 Precision Thickness Gauge

Features:

  • Interface Echo (I-E) Echo-Echo (E-E) ) & Plastic Mode (PLAS) measurement modes
  • Measurement range from 0.15mm (0.006") to 25.40mm (1.00")
  • 2-Point, 1-Point, Material, Thickness Set and Factory Calibration options
  • User selectable measurement rate; 4,8,16 readings per second
  • User selectable reading resolution; 0.1mm (0.01") or 0.01mm (0.001")
  • USB output to ElcoMaster®

Select a transducer

 

Interface Echo (I-E) Measurement Mode Echo Echo (E-E) Measurement Mode Plastic Mode (PLAS) Measurement Mode Measurement Rate of 4Hz Measurement Rate of 8Hz Measurement Rate of 16Hz 

Elcometer NDT Precision Thickness Gauge PTG6
Elcometer NDT Precision Thickness Gauge PTG6Elcometer NDT Precision Thickness Gauge PTG6Elcometer NDT Precision Thickness Gauge PTG6

Technical Specification

Part Number (with Transducer)1

PTG6-TXC

Part Number (gauge only)

PTG6

Easy to use menu structure in multiple languages

Tough, impact, waterproof and dust resistant equivalent to IP54

Bright colour screen with permanent backlight

Ambient light sensor, with adjustable brightness

Scratch and solvent resistant display; 2.4" (6cm) TFT

Large positive feedback buttons

USB power supply via PC

Gauge software updates2 via ElcoMaster® Software

2 year gauge warranty3

Measurement Rate

4, 8, 16Hz4

Measurement Mode

Range5 Accuracy6    

Echo-Echo (E-E)

0.15-10.15mm
(0.006-0.400")
±0.015mm (0.15-2.99mm)
±0.5% (3.00-10.15mm)
±0.0006" (0.006-0.117")
±0.5% (0.118-0.400")

Interface Echo (I-E)

1.65-25.40mm
(0.065-1.000")
±0.015mm (1.65-2.99mm)
±0.5%(3.00-25.4mm)
±0.0006" (0.065-0.117")
±0.5% (0.118-1.000")

Plastic Mode (PLAS)

0.15-5.00mm
(0.006-0.197")
±0.015mm (0.15-2.99mm)
±0.5% (3.00-5.00mm)
±0.0006" (0.006-0.117")
±0.5% (0.118-0.197")

Measurement Units

mm or inches

Repeatability / Stability Indicator

Display Mode

 

Reading

Selectable Reading Resolution

 

Lo; 0.1mm, 0.01 Inch, 10m/s, or 0.001 in/μs

Hi; 0.01mm, 0.001 Inch, 1m/s, or 0.0001 in/μs

Calibration Options

 

1 - point

2 - point

Material selection; 39 preset materials

Factory; resets to the factory calibration

Velocity (speed of sound)

Calibration Features

 

Calibration lock; with optional PIN Lock

Test calibration feature

Data Output

 

USB to PC

ElcoMaster® software

Transducer Probe Type

Single Element

Auto transducer recognition

Auto V-path correction

Battery Type7

2 x AA

Battery Life7

Alkaline: 15 hours
Lithium: 28 hours

Operating Temperature

-10 to 50°C (14 to 122°F)

Size (w x h x d)

145 x 73 x 37mm (5.7 x 2.84 x 1.46")

Weight (including batteries)

210g (7.4oz)

Packing List

  Elcometer PTG6, 15MHz 1/4" Microdot right angle single element transducer, couplant, wrist harness,
3 x screen protector, protective case, plastic transit case, 2 x AA batteries, calibration certificate,
two year warranty extension card, operating instructions

 

STANDARDS:

EN14127, EN15317

 

1 Supplied with 15MHz 1/4"Microdot right angle single element transducer

2 Internet connection required

3 The Elcometer MTG range is extendable within 60 days from date of purchase, free of charge to two years

4 User selectable default setting in scan mode is 16 Hz

5 Dependent on the material being measured and the transducer being used

6 On steel

7 Supplied with Alkaline, Lithium and rechargable can be used with the gauges, continuous use at 1 reading per second

 

Transducers

 

PTG Transducers  
The PTG range of intelligent single element transducers has an automatic transducer recognition which ensures correct probe identification even when the transducer is changed. PTG Transducer 

 

 

 

 

 

Suitable for measuring

Suitable for

Part Number

Probe

Diameter

Probe

Characteristic

Damping

Thin

Plastics

Steel

Aluminium

Titanium

PTG6

PTG8

                 

15.0 MHz Single Element Transducer

TXC15M0CM

1/4"

Right Angle

S

                 

20.0 MHz Single Element Transducer

TXC20M0CM

1/4"

Right Angle

S

 

All transducers are supplied with a calibration certificate.

Accessories

Calibration Standard Sets

Part Number Description 

T920CALSTD-SET1

Calibration Standard Set;
Nominal Thickness; 2-30mm (0.08-1.18")1
Comprising of nominal thickness; 2, 5, 10, 15, 20, 25 & 30mm (0.08, 0.20, 0.39, 0.59, 0.79, 0.98 & 1.18"), complete with holder and calibration certificate. 

T920CALSTD-SET2

Calibration Standard Set;
Nominal Thickness; 40 - 100mm (1.57 - 3.94")1
Comprising of nominal thickness; 40, 50, 60, 70, 80, 90 & 100mm (1.57, 1.97, 2.36, 2.76, 3.15, 3.54 & 3.94"), complete with holder and calibration certificate 

T920CALSTD-HLD

Calibration Holder;

for thicknesses up to 100mm (3.94")

     

Individual Calibration Standards

Part Number

Nominal Thickness (mm)

Nominal Thickness (inches)1

T920CALSTD-2

2 0.078

T920CALSTD-5

5 0.196

T920CALSTD-10

10 0.393

T920CALSTD-15

15 0.590

T920CALSTD-20

20 0.787

T920CALSTD-25

25

0.984

T920CALSTD-30

30 1.181

T920CALSTD-40

40 1.574

T920CALSTD-50

50

1.966

T920CALSTD-60

60

2.362

T920CALSTD-70

70

2.755

T920CALSTD-80

80

3.149

T920CALSTD-90

90

3.543

T920CALSTD-100

100 3.937

 

   

Ultrasonic Couplant

T92015701

Ultrasonic Couplant; 120ml (4fl oz)

T92015701-5

Ultrasonic Couplant; 120ml (4fl oz), Pack of 5 Bottles

T92024034-7

Ultrasonic Couplant; 300ml (10fl oz)

T92024034-8

Ultrasonic Couplant; 500ml (17fl oz)

T92024034-3

Ultrasonic Couplant; 3.8l (1 US Gallon)

T92024034-9

High Temperature Couplant; 60ml (2fl oz)

T92024034-10

High Temperature Couplant; 60ml (2fl oz), Pack of 2

 

 

 

Transducer Adaptor

 

These adaptors allow single & dual element, 'non-intelligent' and other transducers with lemoconnectors from Elcometer NDT and other manufacturers, to be used with the MTG & PTG product range.

Part Number

Description

T92025657

Transducer Adaptor Single Element2

 

 

 

Delay Lines

 

 

Each single element transducer is supplied complete with 9mm and 12mm acrylic delay lines suitable for measuring on steel, aluminium and titanium. If measuring on thin plastics using Plastic Mode (PLAS), a graphite delay line must be used.

Part Number

Description 

T92016528

Acrylic Delay Line; 1/4 Dia x 9mm

T92016529

Acrylic Delay Line; 1/4 Dia x 12mm

T92023853-4

Graphite Delay Line; 1/4 Dia x 3/8"

 

1 Imperial values for information purposes only. Calibration standards are manufactured and measured in millimeters.

This adaptor allows single element, 'non-intelligent' and other transducers with Lemo Connectors from Elcometer and other manufacturers to be used with the PTG product range.

Instruction Manual

@PRODUCT_MANUAL

Data Sheet

@PRODUCT_DATA_SHEET